| TYPE | DESCRIPTION | SAMPLE DATE | RATING | |
|
|
Mar 1 2002 2:32PM | |||
| Comments: This unit is being rated marginal based on the vibration and ultrasound test results. Resample for Ferrographic Analysis due to the large amount of time since the last analysis. | ||||
| Overall Rating History
|
||||
Test Results Used for This Rating
|
| TYPE | DESCRIPTION | SAMPLE DATE | RATING |
| Ultrasound | Jan 29 2002 3:57PM | ||
| Comments: The decibel reading at point 72 is significantly higher than expected. | |||
| TYPE | DESCRIPTION | SAMPLE DATE | RATING |
| Thermography | Jan 29 2002 3:59PM | ||
| Comments: The temperatures are higher than expected. | |||
| TYPE | DESCRIPTION | SAMPLE DATE | RATING |
| Vibration | Mar 1 2002 2:23PM | ||
| Comments: The bearing fault frequencies continue to be present. | |||
| TYPE | DESCRIPTION | SAMPLE DATE | RATING |
| WPA | Sep 22 2001 8:28AM | ||
| Comments: Schedule this unit for an inspection of
the bronze bearing retainers and bushings for severe abnormal wear. Check
also for abnormal wear of the bearing races and rollers. Inspection of the
gear teeth is advised. |
|||
![]()